CAT: BFP/VCAR
C4V0422*2
IE/C4V0422*2/003/2012 SHEET: 1/1
9
1
3
2
4
D* C* A* H* Y*
1
3
2
4
1
3
2
4
1
3
2
4
1
3
2
4
C4V 04 22 * 2 F * * ** 1
Q (l/min)
P(bar)
0
25
50
75
175
100
200
125
225
150
250
0
24
6810
12 14
16 18
B
A
C
1
2
3
4
5
6
02 10412
61
4
81
618
0
2
4
6
8
10
12
14
16
18
20
Q (l/min)
P(bar)
Ø20
Ø12.7
Ø14.27
Ø15.87
3
4 2
1
24
53.838.513
3/4-16 UNF
2.5
112.8
47.8
36
23.5
Ø10
8
2 Corsa
(Stroke)
SOLENOID VALVES 4 WAY 2 POSITIONS
HYDRAULIC FEATURES
PRESSURE DROPS
Max. working pressure 250 bar
Max. Flow 18 l/min
Max. excitation frequency 2 Hz
Duty cycle 100% ED
Hydraulic fluid DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Type of protection (in relation to the
connector used)
IP 65
Weight 0.34 kg
Cartridge tightening torque 25 ÷ 30 Nm
Emergency P1 tightening torque 7 Nm
Cavity (3/4 - 16 UNF) CD018001 (See section 15)
LIMIT OF USE
ORDERING CODE
The tests were carried out with the solenoids 22W at operating temperature, with a
supply voltage 10% below nominal value and with a 40°C fluid temperature.
The fluid used is a mineral oil with viscosity of 46 mm²‘/s at 40°C.
SOLENOID VALVES - 3-4 WAY
Emergency
Connector to be ordered separately, see sect. 18
Spool
type
Connections (pressure drops)
31 32 34 21 41
D
5 5 3 3
C
4 3
A
2 6
3
H
2
4 1
Y
5 3 3
Curve No.
Spool
type
Limits of use - inlet flow port 3
Pressure in 2 Pressure in 4
D
A A
C
A A
A
B C
H
A
Y
A
Curve No.
SPOOL SCHEME
F = Seat
* = See “Spool scheme”
04 = 3/4 - 16 UNF
Voltage
Variants
C3V = Solenoid valve 4 way / 2 positions
S = Without
emergency
E = With
emergency
1 = Serial No.
22 = 22 W (C36)
2 = Position number
Connector to be ordered separately, see sect. 18
00 = No variants
FK =
Flying
600 mm (1)
AJ = AMP Junior
connection (1)
Series
Size
Spool
Coil
Seat type
(1) Only voltages 12 VDC - 24 VDC
(2) With rectifier: 24VAC/50-60Hz
(3) With rectifier: 115Vac/50Hz - 120Vac/60Hz
(4) With rectifier: 230Vac/50Hz - 240Vac/60Hz
(5) Performance are guaranteed only using valves completed with BFP coil
Coils technical data, see sect. 17
DC 22W (C36)
L = 12 VDC
M = 24 VDC
N = 48 VDC
2 = 21.6 VDC RAC (2)
Z = 102 VDC RAC (3)
X = 205 VDC RAC (4)
W = Without coil (5)
The electric valve is a 4-way 2-position directional electrically controlled
valve.
Slight leakage is tolerated for this type of valve.
Available in 5 layouts.
The valves work with DC coils whereas RAC coils with a connector with incor-
porated rectifier must be used for AC applications.
The sleeve is in galvanised steel. The plunger is in tempered and ground steel.
00012029
Spare seals kit
Page: 83
HOME INFO VALVES INDEX